Detail HANNA, HI 3512 New Two Channel, PH/ ORP/ ISE, EC/ TD/ NaCl/ Resistivity Benchtop Meter
The HI 3512 instrument is a state of the art, professional bench meter with a graphic LCD, designed to provide accurate laboratory
results.
This instrument can also measure with ORP electrodes ( pH channel input) , thanks to their capability to measure mV with a resolution up to 0.1 mV and with ISE electrodes on ppm scale ( pH channel input) . The electrode type and unit selection capability and the ISE calibration in up to five calibration standard solutions make this instrument very useful for a large range of concentration solutions measurements. Relative mV feature is available as well as measurement in resistivity, TDS and salinity on the EC channel.
Two input channels are available.
Channel 1: pH/ mV/ ISE and temperature
Channel 2: EC/ TDS, NaCl/ resistivity and temperature
pH channel:
7 standard pH buffers ( pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) for calibration
Up to 5 point pH calibration
Custom calibration with up to two custom buffers
Messages on the graphic LCD for an easy and accurate calibration.
Diagnostics to alert the user when the electrode needs cleaning
User selectable “ out of calibration range“ warning
User selectable “ calibration timeout“ to remind when a new calibration is necessary
Extended temperature range on pH channel from – 20 to 120 º C ( – 4 to 248 º F) , using HI 7662-T temperature probe
EC channel:
7 memorized standards ( 0.00 ¼ S/ cm, 84.0 ¼ S/ cm, 1.413 mS/ cm,
5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm and 111.8 mS/ cm) for calibration
EC calibration up to two calibration points
Messages on the graphic LCD for an easy and accurate calibration
Diagnostics to alert the user when the electrode needs cleaning
User selectable “ out of calibration range” warning
User selectable “ calibration timeout” to remind when a new calibration is necessary
Extended temperature range on EC channel from – 20 to 120 º C ( – 4 to 248 º F) , using a temperature sensor inside the EC probe
Temperature compensation selection
Temperature reference selection 15 ° C, 20 ° C or 25 ° C.
Temperature coefficient set
Lock and user setup fixed range selection
Other features include:
Log on demand up to 400 samples
Log interval with log on stability feature up to 600 records
Auto HOLD feature, to freeze first stable reading on the LCD
GLP feature, to view last calibration data for pH, rel mV, ISE, EC or NaCl
PC interface
pH Range -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
pH Resolution 000.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ± 0.01 pH; ± 0.002 pH
mV Range ± 2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ± 0.2 mV
ISE Range 1.00 e-7 to 9.99 e10 conc.
ISE Resolution 3 digits 0.01, 0.1, 1, 10 conc.
ISE Accuracy ± 0.5% of reading ( monovalent ions) ; ± 1% of reading ( divalent ions)
Temperature Channel 1 Range – 20.0 to 120.0 º C ( 4.0 to 248.0 º F)
Temperature Channel 1 Resolution 0.1 º C ( 0.1 º F)
Temperature Channel 1 Accuracy ± 0.2 º C ( ± 0.4 º F) ( excluding probe error)
Relative mV Offset Range ± 2000 mV
pH Calibration up to five-point calibration, 7 standard buffers available ( 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) , and 2 custom buffers
Slope Calibration from 80 to 110%
pH Temperature Compensation manual or automatic from – 20.0 to 120.0 º C ( – 4.0 to 248.0 º F)
pH Electrode Hi 1131B glass body pH electrode with BnC connector and 1 m ( 3.3' ) cable ( included)
Temperature probe Hi 7662-t temperature probe with 1 m ( 3.3' ) cable ( included)
ISE Calibration up to five-point calibration points 6 standard solutions available ( 0.1, 1, 10, 100, 1000, 10000 ppm)
EC Range 000 to 400 ms/ cm ( shows values up to 1000 ms/ cm) actual conductivity 1000 ms/ cm; 0.001 to 9.999 µ s/ cm; 10.00 to 99.99 µ s/ cm; 100.0 to 999.9 µ s/ cm; 1.000 to 9.999 ms/ cm; 10.00 to 99.99 ms/ cm; 100.0 to 999.9 ms/ cm; 1000 ms/ cm ( autoranging)
EC Resolution 0.001 µ s/ cm; 0.01 µ s/ cm; 0.1 µ s/ cm; 0.001 ms/ cm; 0.01 ms/ cm; 0.1 ms/ cm; 1 ms/ cm
EC Accuracy ± 1% of reading ( ± 0.01 µ s/ cm or 1 digit whichever is greater) excluding probe error
Resistivity Range 01.0 to 199.9 ohms; 100 to 1.999 ohms; 1.00 to 19.99 Kohms; 10.0 to 199.9 Kohms; 100 to 1.999 Kohms; 1.00 to 19.99 Mohms; 10.0 to 100.0 Mohms ( autoranging)
Resistivity Resolution 0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms
Resistivity Accuracy ± 1% of reading ( ± 10 ohms or 1 digit whichever greater) excluding probe error
TDS Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/ L; 10.00 to 99.99 g/ L; 100.0 to 400.0 g/ L ( autoranging)
TDS Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 g/ L; 0.01 g/ L; 0.1 g/ L
TDS Accuracy ± 1% of reading ( ± 0.05 ppm or 1 digit whichever greater) excluding probe error
TDS Factor 0.40 to 1.00
Salinity Range % naCl: 0.0 to 400.0 %
Salinity Resolution 0.1 %
Salinity Accuracy ± 1% of reading excluding probe error
Temperature Channel 2 Range -20.0 to 120° C
Temperature Channel 2 Resolution 0.1° C
Temperature Channel 2 Accuracy ± 0.2 ° C ( excluding probe error)
EC Calibration automatic up to 2 points with 7 memorized standards ( 0.00 µ s/ cm, 84.0 µ s/ cm, 1.413 ms/ cm, 5.00 ms/ cm, 12.88 ms/ cm, 80.0 ms/ cm, 111.8 ms/ cm)
Constant Cell Setup 0.010 to 10.000
NaCl Calibration max. 1 point only ( with Hi 7073 standard)
EC Probe Hi 76310 platinum 4-ring conductivity/ tDs probe with 1 m ( 3.3' ) cable ( included)
Temperature Source automatic from sensor inside the probe; manual entry
EC Temperature Compensation NoTC, MTC, ATC
Reference Temperature 15, 20, 25 ° C
Temperature Coeficient 0.00 to 10.00 % / ° C
Log On Demand 400 samples
Lot Logging pH electrode and buffer condition
PC interface opto-isolated UsB
Input Impedance 1012 ohms
Power Supply 12 VDC adapter ( included)
Environment 0 to 50 ° C ( 32 - 122 ° F) RH max 55% non-condensing
Dimensions 235 x 207 x 110 mm ( 9.2 x 8.14 x 4.33” )
Weight 1.8 Kg ( 4.1 lbs.)
Solutions
HI 6016 7.413 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6004 4.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6007 7.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6010 10.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6124 12.450 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 7030L 12880 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7031L 1413 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7033L 84 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7034L 80000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7035L 111800 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7039L 5000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7037L Calibration solution for % Readings ( 100% NaCl)
1 x 500 mL bottle
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software for Logging Instruments,
Photometers and Turbidity Meters
HI 920013 USB cable
HI 3512 is supplied with HI 76310 conductivity/ TDS probe, HI 1131B pH electrode, HI 7662-T temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 electrode cleaning solution sachet ( 2) , HI 7071S electrolyte solution ( 30 mL) , HI 76404N electrode holder, 12 VDC adapter and instructions. Search HANNA
Search By:
All Products
MSDS Manuals
Products
Chemical Test Kits
pH/ ORP/ ISE Meters
Conductivity/ TDS
Dissolved Oxygen
Multiparameter
Fertigation Systems
Titration Systems
Chemical Oxygen Demand
Photometers
Turbidity Meters
Temperature
Relative Humidity
Magnetic Stirrers
Mini Panel Mounted Controllers
Process Instrumentation
Dosing Pumps
Lux Meters
Reagents
Instrumentation Accessories
pH Range -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
pH Resolution 000.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ± 0.01 pH; ± 0.002 pH
mV Range ± 2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ± 0.2 mV
ISE Range 1.00 e-7 to 9.99 e10 conc.
ISE Resolution 3 digits 0.01, 0.1, 1, 10 conc.
ISE Accuracy ± 0.5% of reading ( monovalent ions) ; ± 1% of reading ( divalent ions)
Temperature Channel 1 Range – 20.0 to 120.0 º C ( 4.0 to 248.0 º F)
Temperature Channel 1 Resolution 0.1 º C ( 0.1 º F)
Temperature Channel 1 Accuracy ± 0.2 º C ( ± 0.4 º F) ( excluding probe error)
Relative mV Offset Range ± 2000 mV
pH Calibration up to five-point calibration, 7 standard buffers available ( 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) , and 2 custom buffers
Slope Calibration from 80 to 110%
pH Temperature Compensation manual or automatic from – 20.0 to 120.0 º C ( – 4.0 to 248.0 º F)
pH Electrode Hi 1131B glass body pH electrode with BnC connector and 1 m ( 3.3' ) cable ( included)
Temperature probe Hi 7662-t temperature probe with 1 m ( 3.3' ) cable ( included)
ISE Calibration up to five-point calibration points 6 standard solutions available ( 0.1, 1, 10, 100, 1000, 10000 ppm)
EC Range 000 to 400 ms/ cm ( shows values up to 1000 ms/ cm) actual conductivity 1000 ms/ cm; 0.001 to 9.999 µ s/ cm; 10.00 to 99.99 µ s/ cm; 100.0 to 999.9 µ s/ cm; 1.000 to 9.999 ms/ cm; 10.00 to 99.99 ms/ cm; 100.0 to 999.9 ms/ cm; 1000 ms/ cm ( autoranging)
EC Resolution 0.001 µ s/ cm; 0.01 µ s/ cm; 0.1 µ s/ cm; 0.001 ms/ cm; 0.01 ms/ cm; 0.1 ms/ cm; 1 ms/ cm
EC Accuracy ± 1% of reading ( ± 0.01 µ s/ cm or 1 digit whichever is greater) excluding probe error
Resistivity Range 01.0 to 199.9 ohms; 100 to 1.999 ohms; 1.00 to 19.99 Kohms; 10.0 to 199.9 Kohms; 100 to 1.999 Kohms; 1.00 to 19.99 Mohms; 10.0 to 100.0 Mohms ( autoranging)
Resistivity Resolution 0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms
Resistivity Accuracy ± 1% of reading ( ± 10 ohms or 1 digit whichever greater) excluding probe error
TDS Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/ L; 10.00 to 99.99 g/ L; 100.0 to 400.0 g/ L ( autoranging)
TDS Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 g/ L; 0.01 g/ L; 0.1 g/ L
TDS Accuracy ± 1% of reading ( ± 0.05 ppm or 1 digit whichever greater) excluding probe error
TDS Factor 0.40 to 1.00
Salinity Range % naCl: 0.0 to 400.0 %
Salinity Resolution 0.1 %
Salinity Accuracy ± 1% of reading excluding probe error
Temperature Channel 2 Range -20.0 to 120° C
Temperature Channel 2 Resolution 0.1° C
Temperature Channel 2 Accuracy ± 0.2 ° C ( excluding probe error)
EC Calibration automatic up to 2 points with 7 memorized standards ( 0.00 µ s/ cm, 84.0 µ s/ cm, 1.413 ms/ cm, 5.00 ms/ cm, 12.88 ms/ cm, 80.0 ms/ cm, 111.8 ms/ cm)
Constant Cell Setup 0.010 to 10.000
NaCl Calibration max. 1 point only ( with Hi 7073 standard)
EC Probe Hi 76310 platinum 4-ring conductivity/ tDs probe with 1 m ( 3.3' ) cable ( included)
Temperature Source automatic from sensor inside the probe; manual entry
EC Temperature Compensation NoTC, MTC, ATC
Reference Temperature 15, 20, 25 ° C
Temperature Coeficient 0.00 to 10.00 % / ° C
Log On Demand 400 samples
Lot Logging pH electrode and buffer condition
PC interface opto-isolated UsB
Input Impedance 1012 ohms
Power Supply 12 VDC adapter ( included)
Environment 0 to 50 ° C ( 32 - 122 ° F) RH max 55% non-condensing
Dimensions 235 x 207 x 110 mm ( 9.2 x 8.14 x 4.33” )
Weight 1.8 Kg ( 4.1 lbs.)
Solutions
HI 6016 7.413 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6004 4.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6007 7.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6010 10.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6124 12.450 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 7030L 12880 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7031L 1413 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7033L 84 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7034L 80000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7035L 111800 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7039L 5000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7037L Calibration solution for % Readings ( 100% NaCl)
1 x 500 mL bottle
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software for Logging Instruments,
Photometers and Turbidity Meters
HI 920013 USB cable
HI 3512 is supplied with HI 76310 conductivity/ TDS probe, HI 1131B pH electrode, HI 7662-T temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 electrode cleaning solution sachet ( 2) , HI 7071S electrolyte solution ( 30 mL) , HI 76404N electrode holder, 12 VDC adapter and instructions. Search HANNA
Search By:
All Products
MSDS Manuals
Products
Chemical Test Kits
pH/ ORP/ ISE Meters
Conductivity/ TDS
Dissolved Oxygen
Multiparameter
Fertigation Systems
Titration Systems
Chemical Oxygen Demand
Photometers
Turbidity Meters
Temperature
Relative Humidity
Magnetic Stirrers
Mini Panel Mounted Controllers
Process Instrumentation
Dosing Pumps
Lux Meters
Reagents
Instrumentation Accessories
pH Range -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH
pH Resolution 000.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ± 0.01 pH; ± 0.002 pH
mV Range ± 2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ± 0.2 mV
ISE Range 1.00 e-7 to 9.99 e10 conc.
ISE Resolution 3 digits 0.01, 0.1, 1, 10 conc.
ISE Accuracy ± 0.5% of reading ( monovalent ions) ; ± 1% of reading ( divalent ions)
Temperature Channel 1 Range – 20.0 to 120.0 º C ( 4.0 to 248.0 º F)
Temperature Channel 1 Resolution 0.1 º C ( 0.1 º F)
Temperature Channel 1 Accuracy ± 0.2 º C ( ± 0.4 º F) ( excluding probe error)
Relative mV Offset Range ± 2000 mV
pH Calibration up to five-point calibration, 7 standard buffers available ( 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) , and 2 custom buffers
Slope Calibration from 80 to 110%
pH Temperature Compensation manual or automatic from – 20.0 to 120.0 º C ( – 4.0 to 248.0 º F)
pH Electrode Hi 1131B glass body pH electrode with BnC connector and 1 m ( 3.3' ) cable ( included)
Temperature probe Hi 7662-t temperature probe with 1 m ( 3.3' ) cable ( included)
ISE Calibration up to five-point calibration points 6 standard solutions available ( 0.1, 1, 10, 100, 1000, 10000 ppm)
EC Range 000 to 400 ms/ cm ( shows values up to 1000 ms/ cm) actual conductivity 1000 ms/ cm; 0.001 to 9.999 µ s/ cm; 10.00 to 99.99 µ s/ cm; 100.0 to 999.9 µ s/ cm; 1.000 to 9.999 ms/ cm; 10.00 to 99.99 ms/ cm; 100.0 to 999.9 ms/ cm; 1000 ms/ cm ( autoranging)
EC Resolution 0.001 µ s/ cm; 0.01 µ s/ cm; 0.1 µ s/ cm; 0.001 ms/ cm; 0.01 ms/ cm; 0.1 ms/ cm; 1 ms/ cm
EC Accuracy ± 1% of reading ( ± 0.01 µ s/ cm or 1 digit whichever is greater) excluding probe error
Resistivity Range 01.0 to 199.9 ohms; 100 to 1.999 ohms; 1.00 to 19.99 Kohms; 10.0 to 199.9 Kohms; 100 to 1.999 Kohms; 1.00 to 19.99 Mohms; 10.0 to 100.0 Mohms ( autoranging)
Resistivity Resolution 0.1 ohm; 1 ohm; 0.01 Kohms; 0.1 Kohms; 1 Kohms; 0.01 Mohms; 0.1 Mohms
Resistivity Accuracy ± 1% of reading ( ± 10 ohms or 1 digit whichever greater) excluding probe error
TDS Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/ L; 10.00 to 99.99 g/ L; 100.0 to 400.0 g/ L ( autoranging)
TDS Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 g/ L; 0.01 g/ L; 0.1 g/ L
TDS Accuracy ± 1% of reading ( ± 0.05 ppm or 1 digit whichever greater) excluding probe error
TDS Factor 0.40 to 1.00
Salinity Range % naCl: 0.0 to 400.0 %
Salinity Resolution 0.1 %
Salinity Accuracy ± 1% of reading excluding probe error
Temperature Channel 2 Range -20.0 to 120° C
Temperature Channel 2 Resolution 0.1° C
Temperature Channel 2 Accuracy ± 0.2 ° C ( excluding probe error)
EC Calibration automatic up to 2 points with 7 memorized standards ( 0.00 µ s/ cm, 84.0 µ s/ cm, 1.413 ms/ cm, 5.00 ms/ cm, 12.88 ms/ cm, 80.0 ms/ cm, 111.8 ms/ cm)
Constant Cell Setup 0.010 to 10.000
NaCl Calibration max. 1 point only ( with Hi 7073 standard)
EC Probe Hi 76310 platinum 4-ring conductivity/ tDs probe with 1 m ( 3.3' ) cable ( included)
Temperature Source automatic from sensor inside the probe; manual entry
EC Temperature Compensation NoTC, MTC, ATC
Reference Temperature 15, 20, 25 ° C
Temperature Coeficient 0.00 to 10.00 % / ° C
Log On Demand 400 samples
Lot Logging pH electrode and buffer condition
PC interface opto-isolated UsB
Input Impedance 1012 ohms
Power Supply 12 VDC adapter ( included)
Environment 0 to 50 ° C ( 32 - 122 ° F) RH max 55% non-condensing
Dimensions 235 x 207 x 110 mm ( 9.2 x 8.14 x 4.33” )
Weight 1.8 Kg ( 4.1 lbs.)
Solutions
HI 6016 7.413 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6004 4.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6007 7.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6010 10.010 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 6124 12.450 pH Millesimal Buffer Solution ( ± 0.002 pH)
1 x 500 mL bottle
HI 7030L 12880 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7031L 1413 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7033L 84 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7034L 80000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7035L 111800 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7039L 5000 µ S/ cm ( µ mho/ cm)
1 x 500 mL bottle
HI 7037L Calibration solution for % Readings ( 100% NaCl)
1 x 500 mL bottle
HI 7061L General Purpose Cleaning Solution
1 x 500 mL bottle
HI 70300L Electrode Storage Solution
1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software for Logging Instruments,
Photometers and Turbidity Meters
HI 920013 USB cable
HI 3512 is supplied with HI 76310 conductivity/ TDS probe, HI 1131B pH electrode, HI 7662-T temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 electrode cleaning solution sachet ( 2) , HI 7071S electrolyte solution ( 30 mL) , HI 76404N electrode holder, 12 VDC adapter and instructions. Search HANNA
Search By:
All Products
MSDS Manuals
Products
Chemical Test Kits
pH/ ORP/ ISE Meters
Conductivity/ TDS
Dissolved Oxygen
Multiparameter
Fertigation Systems
Titration Systems
Chemical Oxygen Demand
Photometers
Turbidity Meters
Temperature
Relative Humidity
Magnetic Stirrers
Mini Panel Mounted Controllers
Process Instrumentation
Dosing Pumps
Lux Meters
Reagents
Instrumentation Accessories
Tampilkan Lebih Banyak