Back to Top

Hi, Guest!

BOD OxiDirect

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karunia Makmur Persada Merupakan Kontraktor Pengadaan Terlengkap Sekaligus Sebagai Importir Alat Instrument di Kota Medan. Kami Melayani Pengadaan di Lembaga Pemerintahan dan Swasta Diseluruh Indonesia.

Detail BOD OxiDirect

BOD OxiDirect Catalogue extract Environment Catalogue extract Photos OxiDirect_ Detail_ 1 OxiDirect_ Einzel tintometer11OxiDirect_ De tail_ 1 tintometer13Zubehö r Instructions BODBOD OxiDirect Anleitung gb BOD OxiDirect Anleitung de BOD OxiDirect Anleitung fr BOD OxiDirect Anleitung es BOD OxiDirect Anleitung pt BOD - Datatransmission with HyperterminalBOD OxiDirect Anleitung gb BOD - Test Set BOD OxiDirect Anleitung multi BOD - with RS 232 interfaceBOD OxiDirect Anleitung gb BOD OxiDirect Anleitung de BOD OxiDirect Anleitung fr BOD OxiDirect Anleitung es Direct and Accurate BOD, 1-28 days measurements, Mercury-free Highlights Direct sample selection Accurate and direct display of BOD values in mg/ l User-friendly handling User-selectable measuring period from 1 to 28 days ( BOD5, BOD7, OECD… ) Automatic storage of BOD values Measuring ranges from 0-40 mg/ l to 0-4000 mg/ l BOD / sample volume related Automatic start function following temperature equalisation of the samples Mercury-free, environmentally-friendly BOD determination Inductive stirring system with automatic re-centering of stirring rods Interface RS 232 Applications Waste Water Determination of Biological Activity Waste Water Treatment plants Analytical Laboratories Research Centers Universities Description BOD BottleRespirometric methods provide direct measurement of the oxygen consumed by microorganisms from an air or oxygen-enriched environment in a closed vessel under conditions of constant temperature and agitation. Carbon dioxide produced metabolically by the bacteria is chemically bound by the potassium hydroxide solution contained in the seal cup in the bottle. The result is a pressure drop in the system, which is directly proportional to the BOD value and is measured by the Lovibond BOD sensor. The BOD level is then displayed directly in mg/ l. The BOD values are stored in the sensor memory and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days – and manometric determination of OECD, for example, generally takes place over a period of 28 days. Measuring ranges and sample volumes The BOD level of a sample depends on the quantity of organic matter present, which can vary considerably. The Lovibond BOD measuring system OxiDirect is therefore calibrated for the various sample volumes and the corresponding measuring ranges listed in the table below. The overall measuring range of the system is 0 – 4000 mg/ l. For all measuring ranges, BOD is shown directly in mg/ l. Evaluation of measurements If the measuring period is set at 24 hours, the Lovibond OxiDirect BOD measuring system records a measurement once every hour. With a measuring period of 48 hours, the unit measures and stores a BOD value once every 2 hours. If the measuring period is between 3 and 28 days, one value is measured and stored each day. Current values and stored values may be called up at any time. The table/ graph below illustrates an example of BOD5 evaluation. The development of BOD over a period of 5 days is easily seen. OxiDirect BOD measuring system In addition to the BOD unit for measurement and storage of BOD levels, the Lovibond OxiDirect BOD measuring system includes sample bottles, measuring sensors, non-wearing inductive stirring system, overflow measuring flasks for metering of sample volumes, nitrification inhibitor and potassium hydroxide as an absorbent. Inductive stirring system The microprocessor-controlled Lovibond inductive stirring system is non-wearing and maintenance-free. In other words, there are no moving parts in the system. cooler box
Tampilkan Lebih Banyak
Kontak Kami