  • GPS Multiparameter Meter with Fast Tracker™ Tag Identification System HI 98280

GPS Multiparameter Meter With Fast Tracker™ Tag Identification System HI 98280

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Karunia Makmur Persada Merupakan Kontraktor Pengadaan Terlengkap Sekaligus Sebagai Importir Alat Instrument di Kota Medan. Kami Melayani Pengadaan di Lembaga Pemerintahan dan Swasta Diseluruh Indonesia.

Detail GPS Multiparameter Meter With Fast Tracker™ Tag Identification System HI 98280

HANNA’ s new HI 9828 multiparameter portable meter with GPS receiver monitors up to 13 different water quality parameters ( 6 measured, 7 calculated) . Measurements from specific locations are tracked with detailed coordinate information that can be viewed immediately on the display. GPS information can be transferred to a PC using HANNA’ s HI 929828 software. GPS information can also be viewed by GPS mapping software such as Google™ maps* . Clicking on visited locations using mapping software such as Google™ Maps displays measurement information. The built-in 12 channel GPS receiver and antenna guarantees a position accuracy of 30 ft ( 10 m) . For measuring points within a 30 ft range or where GPS signals are not available, HI 9828’ s Fast Tracker™ is invaluable for associating measurements with their locations. HANNA’ s exclusive Fast Tracker™ — Tag I.D. System monitors and records data using iButton® s that can be installed at any number of sampling sites. The HI 9828 has a graphic, backlit display that automatically sizes the digits to fit the screen and allows full configuration of each parameter measured along with on-screen graphing capability. The meter incorporates comprehensive GLP features and the downloading of data via USB connection. Each parameter is supported by on-screen context sensitive help, both in the calibration mode and during measurement. Designed for outdoor environments, the meter is impact resistant and waterproof meeting IP67 standards ( 30 minutes immersion under 1 m of water) . The multi sensor probe can be left underwater ( IP68 standard) . GPS ( Global Positioning System) Enabled The new HI 9828 features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. The GPS tracks your location using satellites to within 30 ft ( 10 m) so you can be sure that you return to the same location for repeated measurements. Basic GPS Features • GPS coordinates shown on the LCD with up to 10 measurement parameters • GPS signal strength shown on LCD • Number of satellites shown on LCD • Logged data is embedded with GPS coordinates Advanced GPS Features • Users can associate GPS coordinates with alphanumeric locations • Distances between current location and predefined locations are displayed arranged by distance • Memorizes last location and time should signal be lost Track Measurement Locations Users can connect to GPS tracking software such as Google™ Maps* to view locations where samples have been taken. Measurement information is shown right on the map. HI 929828 PC Software • Manages logged data from the HI 9828 • Displays GPS coordinates with logged data • Automatically maps samples on your PC ( internet connection required) • Shows location points on map along with measurement data Fast Tracker™ Tag Identification System HANNA’ s iButton® Tag Identification System simplifies test logging. iButton® s with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking. Features • Display up to 12 parameters • Track measurement locations with GPS • Meter features IP67 and probe features IP68 waterproof protection • Exclusive Fast Tracker™ — Tag I.D. System simplifies test logging • Graphic LCD with backlight • Built-in barometer for DO compensation • Quick Calibration feature • Measurement check eliminates any erroneous readings • Auto recognition of pH and pH/ ORP probe • Logger function records the data of all connected sensors • Log-on-demand and automatic logging ( up to 60, 000 samples) • Can display logged data as graphs • USB for PC connectivity • Auto-range of EC and TDS readings • Good Laboratory Practice feature with the last 5 calibrations recorded • All sensors are field replaceable • Meter accepts both alkaline and rechargeable batteries • Rugged probe with stainless steel tip has a diameter under 2” for wells and pipes * GOOGLE™ is a registered trademark of Google, Inc. HANNA instruments® has no affiliation with Google™ , Inc. Order Information: HI 98280 is supplied with HI 769828 multisensor probe ( pH/ ORP, EC, DO, temperaure) , HI 9828-25 quick calibration standard solution ( 500 mL) , probe maintenance kit, rechargeable C size Ni-MH batteries ( 4) , power adapter & cable, car 12V accessory outlet adapter, HI 7698281 USB interface cable, HI 92828 Windows® compatible software and instruction manual in a rugged carrying case. * Specifications * Accessories * Downloads Range pH 0.00 to 14.00 pH Resolution pH 0.01 pH Accuracy pH ± 0.02 pH Range mV of pH input ± 600.0 mV Resolution mV of pH input 0.1 mV Accuracy mV of pH input ± 0.5 mV Range ORP ± 2000.0 mV Resolution ORP 0.1 mV Accuracy ORP ± 1.0 mV Range Dissolved Oxygen 0.0 to 500.0% / 0.00 to 50.00 mg/ L Resolution Dissolved Oxygen 0.1% / 0.01 mg/ L Accuracy Dissolved Oxygen 0.0 to 300.0% : ± 1.5% of reading or ± 1.0% whichever is greater; 300.0 to 500.0% : ± 3% of reading; 0.00 to 30.00 mg/ L: ± 1.5% of reading or 0.10 mg/ L whichever is greater; 30.00 mg/ L to 50.00 mg/ L: ± 3% of reading Range Conductivity 0.000 to 200.000 mS/ cm ( absolute EC up to 400 mS/ cm) Resolution Conductivity Manual: 1 µ S/ cm; 0.001 mS/ cm; 0.01 mS/ cm; 0.1 mS/ cm; 1 mS/ cm; Automatic: 1 µ S/ cm from 0 to 9999 µ S/ cm; 0.01 mS/ cm from 10.00 to 99.99 mS/ cm ; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm; Automatic mS/ cm: 0.001 mS/ cm from 0.000 to 9.999 mS/ cm; 0.01 mS/ cm from 10.00 to 99.99 mS/ cm; 0.1 mS/ cm from 100.0 to 400.0 mS/ cm Accuracy Conductivity ± 1% of reading or ± 1 µ S/ cm whichever is greater Range Resistivity 0 to 999999 © • cm; 0 to 1000.0 k© • cm; 0 to 1.0000 M© • cm Resolution Resistivity Dependent on resistivity reading Range TDS 0 to 400000 mg/ L or ppm ( the maximum value depends on the TDS factor) Resolution TDS Manual: 1 mg/ L ( ppm) ; 0.001 g/ L ( ppt) ; 0.01g/ L ( ppt) ; 0.1 g/ L ( ppt) ; 1 g/ L ( ppt) ; Auto-range scales: 1 mg/ L ( ppm) from 0 to 9999 mg/ L ( ppm) ; 0.01 g/ L ( ppt) from 10.00 to 99.99 g/ L ( ppt) ; 0.1 g/ L ( ppt) from 100.0 to 400.0 g/ L ( ppt) ; Auto-range g/ L ( ppt) scales: 0.001 g/ L ( ppt) from 0.000 to 9.999 g/ L ( ppt) ; 0.01 g/ L ( ppt) from 10.00 to 99.99 g/ L ( ppt) ; 0.1 g/ L ( ppt) from 100.0 to 400.0 g/ L ( ppt) Accuracy TDS ± 1% of reading or ± 1 mg/ L Range Salinity 0.00 to 70.00 PSU ( Extended Practical Salinity Scale) Resolution Salinity 0.01 PSU Accuracy Salinity ± 2% of reading or 0.01 PSU whichever is greater Range Seawater Specific Gravity 0.0 to 50.0 Ã t, Ã 0, Ã 15 Resolution Seawater Specific Gravity 0.1 Ã t, Ã 0, Ã 15 Accuracy Seawater Specific Gravity ± 1 Ã t, Ã 0, Ã 15 Range Atm. Pressure 450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa Resolution Atm. Pressure 0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Accuracy Atm. Pressure ± 3 mmHg within ± 15° C from the temperature during calibration Range Temperature -5.00 to 55.00° C; 23.00 to 131.00° F; 268.15 to 328.15K Resolution Temperature 0.01° C; 0.01° F; 0.01K Accuracy Temperature ± 0.15° C; ± 0.27° F; ± 0.15K Calibration pH Automatic 1, 2, or 3 points with 5 memorized standard buffers ( pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer Calibration ORP Automatic at 1 custom point Calibration Conductivity, Salinity Automatic 1 point with 6 memorized standards ( 84 ¼ S/ cm, 1413 ¼ S/ cm, 5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm, 111.8 mS/ cm) or custom point Calibration Dissolved Oxygen Automatic 1 or 2 points at 0, 100% or 1 custom point Calibration Resistivity, TDS Based on conductivity or salinity calibration Calibration Atm. Pressure Automatic at 1 custom point Calibration Temperature Automatic at 1 custom point Temperature Compensation Automatic from -5 to 55° C ( 23 to 131° F) Logging Memory Up to 60000 samples with 13 measurements each Up to 45, 000 samples with 15 measurements each ( GPS) Logging Interval 1 second to 3 hours Computer Interface USB ( with HI 929828 software) Waterproof Protection Meter IP67, Probe IP68 Environment 0 to 50° C ( 32 to 122° F) ; RH 100% Power Supply ( 4) 1.5V alkaline C cells ( approx. 150 hours of continuous use without backlight) / ( 4) 1.2V rechargeable C cells ( approx. 70 hours of continuous use without backlight) Dimensions Meter 221 x 115 x 55 mm ( 8.7 x 4.5 x 2.2” ) Dimensions Probe 270 x 46 mm DIA ( 10.6 x 1.8" DIA) Weight Meter: 750g ( 26.5 oz.) ; Probe: 750g ( 26.5 oz.)
Tampilkan Lebih Banyak
Kontak Kami