Back to Top

Hi, Guest!

HACH HQ40D Portable DO And Conductivity / TDS Meter With Luminescent

Update Terakhir
:
10 / 04 / 2023
Min. Pembelian
:
1 Unit

Harga

Rp. 123
Karunia Makmur Persada Merupakan Kontraktor Pengadaan Terlengkap Sekaligus Sebagai Importir Alat Instrument di Kota Medan. Kami Melayani Pengadaan di Lembaga Pemerintahan dan Swasta Diseluruh Indonesia.

Detail HACH HQ40D Portable DO And Conductivity / TDS Meter With Luminescent

HACH HQ40D Portable DO and Conductivity / TDS Meter with Luminescent DO Sensor and Conductivity Cell, 1 m Cable

Spesifikasi :

AC Power Adapter and USB/DC Adapter:Included
Automatic Buffer Recognition:Yes
Barometric Pressure Measurement:Automatic compensation of DO when using an LDO or LBOD probe
Calibration:Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days
Compliance Certifications:CE.WEEE
Conductivity measurement:Yes
Conductivity measurement: Temperature correction:None; Linear; NaCl Non-Linear Natural Water.
Conductivity Measurement Range:0.01 µS/cm - 200.0 mS/cm
Conductivity resolution:0.01 µS/cm - 0.1 mS/cm upon selected measuring range
Contents:No
Custom Calibration Standards:Yes
Data Export:Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Data Memory:500 records/FIFO
Data Storage:Automatic, GLP ISO compliant reading data stored with calibration details.
Digital (intelligent) electrode inputs:2 channels
Display:Detailed mode/Large mode
Display Type:240 x 160 pixel LCD with backlight illumination
DO Measurement Range:0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
DO Resolution:0.1
DO sensor calibration:* 100% (water-saturated air (100%) calibration
* 100% with 0 (water-saturated air (100%) calibration with 0 point
* mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution)
* mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point)
* Factory (calibration with the default LDO calibration)
GLP Features:Date; Time; Sample ID; Operator ID
Inputs:2
Instrument:Portable
IP Rating:IP67
ISE Direct Measurement Range:Yes
ISE Electrode Calibration:2 - 5 Points
Kit?:Yes
Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
Lock Function:Continuous / Auto-stabilization ("press to read") / At Interval
Measurement Method:Probe specific programmed method settings
Model:HQ40D – Multi/2 Channels
mV Measurement at Stable Reading:Yes
mV Measurement Range:-1500 - 1500 mV
mV Resolution:0.1 mV
Needed Cable Length:1
Operating Error Messages:Clear text error messages displayed
Operating Humidity:90 % relative humidity (non-condensing)
Operating Interface:Soft Touch Keypad
Operating Temperature:0 - 60 °C (32 - 140 °F)
ORP Electrode Calibration:Predefined ORP standards (including Zobell's solution)
Parameter:pH/Oxydo Reduction Potential (ORP)
Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity
Dissolved Oxygen (DO)
Biochemical Oxygen Demand (BOD)
Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium
Parameters:pH

Dissolved Oxygen
NA
PC Data Transfer Software:HQD Series Meter Data Transfer Utility
pH Buffer Sets:Color-coded: 4.01, 7.00, 10.01 pH;
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45
DIN: 1.09, 4.65, 9.23
User-defined custom buffer sets
pH Electrode calibration:1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range:0 - 14 pH
pH Resolution:Selectable:
0.001/0.01/0.1 pH
Printer:Yes, Optional
Probes included:CDC40101, LDO10101
Probe Type:Intellical Standard Laboratory or Rugged Field
Region:US
Salinity Measurement Range:0 - 42 (ppt) (‰)
Salinity Resolution:0.01 (ppt) (‰)
Sensor A:CDC40101
Sensor B:LDO10101
Sensor C:NA
Sensors:Sensor A: CDC40101
Sensor B: LDO10101
Sensor C:
Simultaneous measurements:Yes, 2 channels
TDS Measurement Range:0.00 mg/L - 50.0 g/L NaCl
TDS Resolution:0.01 mg/L up - 0.1 g/L upon measuring range
Temperature Compensation:Automatic Temperature compensation for pH
Automatic Temperature compensation for pH
Temperature Measurement:°C or °F
Temperature Resolution:0.1
Type of Measurement:Field Measurements
Warranty:3 years
Weight:335 g (0.75 lb) without batteries; 430 g (0.95 lb) with

For the best service and prices contact:

Waty

CV. KARUNIA MAKMUR PERSADA
TRITURA VISTA RUKO COMPLEX BLOK A
JL. M. BASIR NO. A–6 Pangkalan Masyhur, TITI KUNING MEDAN 20143
Tampilkan Lebih Banyak
Kontak Kami