Back to Top

Hi, Guest!
  • KIMIA TEKNIS
  • HANNA, Free & Total Chlorine, pH, ORP and Temperature Analyzer

HANNA, Free & Total Chlorine, PH, ORP And Temperature Analyzer

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Karunia Makmur Persada Merupakan Kontraktor Pengadaan Terlengkap Sekaligus Sebagai Importir Alat Instrument di Kota Medan. Kami Melayani Pengadaan di Lembaga Pemerintahan dan Swasta Diseluruh Indonesia.

Detail HANNA, Free & Total Chlorine, PH, ORP And Temperature Analyzer

Ph Meter
The PCA 330 series of analyzers check pH/ ORP and chlorine levels in applications such as pools and spas, drinking water and influent and effluent discharge of water to ensure public safety, prevent waste and protect the environment by reducing over dosage. Features: • pH regulation with both ON/ OFF and proportional controls • Separate alarms can be set for pH and chlorine controls • Parameters can be sent through SMS • Large graphical display with backlight • User-friendly interface • Can store up to 3500 data, that can be displayed or downloaded to a PC Range Free & Total Chlorine 0.00 to 5.00 mg/ L Range pH 0.00 to 14.00 pH Range Temperature 5.0 to 75.0° C Range mV 0 to 2000 mV Resolution Free & Total Chlorine 0.01 mg/ L Resolution pH 0.01 pH Resolution Temperature 0.1° C Resolution mV 1 mV Accuracy Free & Total Chlorine ± 8% ± 0.05 mg/ L Accuracy pH ± 0.05 pH Accuracy Temperature ± 0.5° C Accuracy mV ± 1 mV Minimum Detectable Level Free & Total Chlorine 0.05 mg/ L Input Impedance 1012 Ohm Calibration Free & Total Chlorine 1 point Calibration pH 1 or 2 point Sampling Rate Free & Total Chlorine adjustable from 3 to 90 minutes Sampling Rate pH adjustable from 3 to 120 seconds Dosage Free & Total Chlorine proportional with 4-20 mA output Dosage pH ON/ OFF with relay or proportional with 4-20 mA output Delta Free & Total Chlorine selectable from 0.1 to 5 mg/ L Delta pH selectable from 0.1 to 2 pH ( hysteresis adjustable from 0.05 to 2 pH) Recorder Output 0-10 mV, 0-100 mV, 4-20 mA or 0-20 mA Serial Communication RS485 port, galvanically isolated Baud Rate 1200, 2400, 4800, 9600 bps Data Logging up to 3500 data series GSM Communication 2 programmable cellular phone numbers, alarm & information SMS using the HI 504900 module ( optional) Alarm Relay SPDT contact with 5A, 230 V resistive load Dosing Relay SPDT contact with 5A, 230 V resistive load System Error SPDT contact with 5A, 230 V resistive load Inlet Pressure 0.07 to 4 bar with no external pressure regulator ( for pressure exceeding 4 bar an external pressure regulator is required) Sample Flow 100 to 300 mL/ min Sample Temperature 5 to 40° C ( 41 to 104° F) Sample Inlet Connection 12 mm ( 1/ 2" ) tubing diameter Drain Connection 10 mm ( 3/ 8" ) bar fitting Power Supply 115 Vac or 230 Vac; 50/ 60 Hz; 20 VA ( See Chart) Enclosure NEMA-4X standard, molded fiberglass polyster with transparent Lexan window Dimensions 318 x 267 x 159 mm ( 12.5 x 10.5 x 6.25" ) Weight 5 kg ( 11 lb.) without reagents
Tampilkan Lebih Banyak
Kontak Kami